MXM1-400 AC MCCB

Product application:

MXM1-400 AC MCCB series is a new type product developed and manufactured by Adopting international advanced technology. It is supplied with rated insulation voltage 800V and used for circuit of AC 50Hz, rated operation voltage AC 400V or below rated operation current up to 1600A for infrequent changing over and starting of the motors. Equipped with the protection devices for over-current, short circuit and under voltage, the product is capable of preventing damage of circuits and supply units. The product conforms to IEC60947-2 standard.

Working Condition:

1、Not over altitude 2000m;
2、Ambient temperature is between -5℃ to+40℃; 
3、Withstand the influence of moist air; 
4、Withstand the influence of smoke fog,salt mist; 
5、Withstand the influence of fungus; 
6、The max. gradient is 22.5℃;
7、Working reliable under the condition of normal vibration in ship; 
8、Working reliable under the condition of earth quake(4g);
9、Working in the medium which not any explosive, no enough dielectric to corrode metal, no gas to damage insulation and elctric conduction dust;
10、Working in the place would not be invaded by rain and snow;

Working Condition:

1、According to the pole number of products,it classifies two-pole(100A, 225A), three-pole(no four-pole for YRM1-800), the neutral pole(N-pole) of the four-pole breakers has four types; 

TypeA: N-pole without over-current release unit, it has been connected all along, and does not act with other three-pole to turn on or off. 
Type B: N-pole without over-current release unit, it could act with other three-pole; 
Type C: N-pole fixed with over-current release unit, it could act with other three-pole; 
Type D: N-pole fixed with over-current release unit, it has been connected all along, and does not act with other three-pole to turn on and off. 

2、According to rated current of products, it classifies: 

MXM1-63: (6),10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, (no over-load protection for 6A); 
MXM1-125: (10), 10A,16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A,100A, 125A; 
MXM1-250: 100A, 125A, 140A, 160A,180A, 200A, 225A, 250A; 
MXM1-400: 225A, 250A, 315A, 350A, 400A; 
MXM1-630: 400A, 500A, 630A; 
MXM1-800: 630A, 700A, 800A; 

3、According to connection mode, it classifies front in wiring,rear in wiring, and plug in type. 

4、According to over-current release type, it classifies the thermodynamic-magnetic (binary) type and magnetic (instantaneous) releases.

Protective Characteristics:

The thermodynamic of a circuit breaker provides the feature of inverse time-delay,while the magnetic release the instantaneous operation as shown on Table 1 (distribution circuit breaker)and Table 2 (motor protection circuit breaker).

Specifications:


Model
Rated Frame Current (A) Rated Current (A) Rated Working Voltage (V) Rated Insulated Voltage (V) Rated Ultimate Short-circuit Breaking Capacity KA 400V Rated Runing Breaking Capacity KA 400V Overall Dimension Mounting Dimension(Front in Wiring)
MXM1-63L 63 6,10,16,20,25,32,40,50,63 AC400V AC500V 25 18 135 78 73.5 25 117 3.5
MXM1-63M 50 35 135 78/103 81.5
MXM1-125L 125 10,16,20,25,32,40,50,63,80,100,125 AC690V AC800V 35 22 150 92 68 30 129 4.5
MXM1-125M 50 35 150 92/122 86
MXM1-125H 85 50
MXM1-250L 250 100,125,140,160,180,200,225,250 AC690V AC800V 35 22 165 107 86 35 12 3.5
MXM1-250M 50 35 165 107/142 86
MXM1-250H 85 50
MXM1-400L 400 225,250,315,350,400 AC690V AC800V 50 35 257 150/198 105 44 194 7
MXM1-400M 65 42 257 150 106.5
MXM1-400H 100 65
MXM1-630L 630 400,500,630 AC690V AC800V 50 35 270 182/240 110 58 200 7
MXM1-630M 65 42 270 182 110
MXM1-630H 100 65 275 210 115.5 70 243 7
MXM1-800M 800 630,700,800 AC690V AC800V 75 50 275 210 115.5 70 243 7
MXM1-800H 100 65

 

Feedback

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.